Design images created by computer and with AI. The actual finish may vary.
LED panels · Fibre-reinforced plaster
CHEVRA
3D wall panel
Battens at 45° and lines of light in a herringbone composition.
- Material
- Fibre-reinforced plaster
- Type
- 3D wall panel
- Finish
- Matt white · Fine mineral texture
Design
Relief,
in a different light.
CHEVRA combines diagonal battens with sixteen grooves designed for exposed lines of light. Alternating rotations build the herringbone and keep the grooves meeting between panels. Plaster panel designed for exposed linear LED light. Designed to house a 24 V silicone LED profile. The LED profile and power supply are specified for each project. Calculated reference weight: 5.40 kg.
Where to use it. Herringbone is a familiar pattern from parquet floors and brick bonds; CHEVRA brings it to the wall with battens at 45° and lines of light. It suits spaces with character: a bar, a shop, the wall of a play area or a living room where lighting is part of the design.
The light. The grooves hold exposed lines of light, flush with the surface, that follow the herringbone zigzag. Each run of light is straight and is connected at the changes of direction. The silicone LED profile and 24 V supply are specified for each project; the mains connection is made by a qualified electrician. Tell us in your enquiry which lines you want to light, the tone of light and the control.

Technical information
Everything for your project.
Explore the features of the piece and the resources to specify your wall cladding.
Specifications
Product details

- Reference
- GYP-LED-072-A-01
- Format
- 500 × 500 mm
- Total thickness
- 9.5–21.8 mm
- Maximum relief
- 12.3 mm
- Reference weight
- 5.4 kg
- Coverage per panel
- 0.25 m²
- Material
- Fibre-reinforced plaster
- Use
- Interior cladding in dry areas
- Finish as supplied
- Matt white, ready to prime and paint
- Panels per m²
- 4 panels/m²
- Repeat
- One module · Alternating 0°/90°
- Reaction to fire
- Tell us the class your project requires
Application
Interior wall cladding. One module · Alternating 0°/90°.
Finish and joints
Joints between panels filled; keep the relief and the lighting housings.
Performance
Reaction to fire
The documentation will be provided with the final product. If your project requires a specific class, mention it in your enquiry.
Calculate your area
Enter the dimensions of your wall.
Calculated from area and waste.
Downloads
CHEVRA documentation
The design data sheet, the collection technical data sheet and the installation guide, ready for your project specification.
To include the cladding in a project specification, tell us what documentation you need.
Request documentation3D and CAD resources
Resources for professionals.
Tell us what you need to represent, which software you use and how CHEVRA fits into your project.
We will look at the right resource for the scale and use of your proposal.
Request professional resourcesTo review your request
- Project type and location.
- Area to be clad.
- Software and working format.
- Intended use: specification, drawing or visualisation.
Installation
A continuous surface.
Alternate pieces at 0° and 90° following the documented herringbone layout. Keep the grooves meeting at the joints. Plan each straight lighting run and its connections at the changes of direction. Fill the joints while keeping the battens and grooves; LED profile and power supply to suit the project. Furniture and light fittings need support independent of the panel.
- 01
Acclimatisation
Leave the pieces in the room for 24 hours in their packaging, and unpack them just before fitting.
- 02
Substrate
Sound, flat, dry and clean. Correct any unevenness and remove loose paint, dust or grease.
- 03
Setting out
Mark out the layout from a level line, following the orientation and rotations given for each design.
- 04
Fixing
Gypsum- or plaster-based adhesive, with additional mechanical fixing where the substrate does not guarantee adhesion.
- 05
Joints
Fill with plaster or fine gypsum filler and sand, keeping the channels, steps and edges that are part of the design.
- 06
Priming and painting
Prime the whole surface and paint on site with an interior paint suitable for plaster, in the colour of your choice.
Delivery
Once your project is defined.
We look at each project individually. Availability, lead times, quantities and transport are confirmed in our reply to your enquiry, with no obligation.
Quantities
We work out the pieces from the area and layout of your wall. The calculator on this page gives you a first estimate.
Destination
Tell us the country, postcode and any access or unloading conditions so we can look at transport.
Lead times and conditions
Lead time, packaging and delivery conditions are confirmed in each proposal. Sending an enquiry is not an order or a reservation.

Sample
The material, in your own light.
Study the relief, the texture and how it works with the other materials in your project.
Request the CHEVRA sample and we will write to you personally as soon as it is available.
Request a sampleFrequently asked questions
Before you define your wall.
Are the joints between panels visible?
Installation joints are finished according to the design's instructions. The intentional channels and steps that are part of the relief are kept.
How are the pieces laid?
Alternate pieces at 0° and 90° following the documented herringbone layout. Keep the grooves meeting at the joints. Plan each straight lighting run and its connections at the changes of direction. Fill the joints while keeping the battens and grooves; LED profile and power supply to suit the project. Furniture and light fittings need support independent of the panel.
Can the panels be painted?
Yes. They will be supplied in matt white and, once the joints are finished, the whole surface is primed and painted on site with an interior paint suitable for plaster, in the colour of your choice.
Where can they be installed?
On interior walls in dry areas: homes, hotels, restaurants, shops and offices. They are not suitable for outdoor use or for areas with direct water or constant humidity.
How do I work out how many pieces I need?
The 500 × 500 mm format covers 0.25 m² per piece: 4 pieces per m² before cuts and waste. The quantity calculator helps you study the area; the layout defines the cuts and junctions.
Go to the calculatorHow do I request documentation for my project?
Download the product data sheet or tell us what you need to include in your specification, drawing or visualisation. Include the project type, the area and the software you work with.
Talk about my project
Samples and projects
From the material
to your project.
Study the relief in your own light. Tell us what you are designing.
Talk about my project







